Amplitude® Flame Resistant FabricAmplitude™, a patent-pending line of premium, high performance flame-resistant (FR) fabrics for industrial workwear. The new proprietary, “Made in USA” fabrics are processed ammonia-free and are constructed of an optimized blend designed to help mitigate potential injuries due to electric arc and flash fire exposure, while providing enhanced durability and comfort. The combination of these capabilities makes it an ideal fabric for industrial workwear occupations in manufacturing, utilities, electrical maintenance, petrochemical, welding, and
steel. Amplitude has enhanced comfort and improved aesthetic qualities, and delivers premium FR performance while enhancing worker comfort through improved breathability and optional stretch. These high performance, FR fabrics by Milliken are UL listed and NFPA 70E, NESC and NFPA 2112 compliant. Download Amplitude Brochure Download Amplitude Whitepaper
|
| 6oz. Twill |
Process Averages* |
Specs* |
Test Method |
| Weight |
6.4 oz/yd2 (+/- 5%) |
6.5 oz/yd2 (+/- 5%) |
ASTM D3776 |
| Width-Min. |
62.5” |
>61.0” cuttable |
|
Tear Strength (lbs W X F) |
13.9 x 6.8 |
>7.0 x >5.0 |
ASTM D1424 |
Tensile Strength (lbs W X F) |
139 x 55 |
>100 x >40 |
ASTM D5034 |
| Air Permeability (cfm) |
141 |
>100 |
ASTM 737 |
Laundry Shrinkage (W X F) |
0.7% x <2.9% |
<3.0% x <3.0% |
ASTM 1506 AATCC 135-3, IV, Aiii |
10 IL** Shrinkage (W X F) |
1.4% x <4.2% |
<5.0% x <5.0% |
** Wash Method as specified by NFPA 2112 |
| TPP (contact/spaced) |
8.1/8.4 |
>3/6 |
NFPA 2112-2007 |
| Vertical Flame |
3.29” |
<4.0” |
ASTM D6413 |
| Thermal Shrinkage |
1.0% x 3.1% |
<10% x <10% |
NFPA 2112-2007 |
| Arc Rating (ATPV) |
8.7 cal/cm2 |
>8.0 |
ASTM F1959 |
| Thermal Manikin |
38.5% avg. |
<50% |
ASTM F1930 |
Certified to ASTM F1506 (NFPA 70E HRC2),CGSB 155.20, NFPA 2112
*Note: "Process Averages" are historical estimates, actual results may vary.
| 7oz. Twill |
Process Averages* |
Specs* |
Test Method |
| Weight |
7.8 oz/yd2 (+/- 5%) |
7.5 oz/yd2 (+/- 5%) |
ASTM D3776 |
| Width-Min. |
64.5” |
>63.0” cuttable |
|
Tear Strength (lbs W X F) |
8.8 x 6.8 |
>7.0 x >5.0 |
ASTM D1424 |
Tensile Strength (lbs W X F) |
155 x 69 |
>100 x >40 |
ASTM D5034 |
| Air Permeability (cfm) |
61 |
>50 |
ASTM 737 |
Laundry Shrinkage (W X F) |
1.8% x <1.2% |
<3.0% x <3.0% |
ASTM 1506 AATCC 135-3, IV, Aiii |
10 IL** Shrinkage (W X F) |
2.3% x <1.3% |
<5.0% x <5.0% |
** Wash Method as specified by NFPA 2112 |
| TPP (contact/spaced) |
9/10 |
>3/6 |
NFPA 2112-2007 |
| Vertical Flame |
3.14” |
<4.0” |
ASTM D6413 |
| Thermal Shrinkage |
2.5% |
<10% |
NFPA 2112-2007 |
| Arc Rating (ATPV) |
9.2 cal/cm2 |
>8.0 |
ASTM F1959 |
| Thermal Manikin |
18.3% avg. |
<50% |
ASTM F1930 |
Certified to ASTM F1506 (NFPA 70E HRC2),CGSB 155.20, NFPA 2112
*Note: "Process Averages" are historical estimates, actual results may vary.
| 9oz. Twill |
Process Averages* |
Specs* |
Test Method |
| Weight |
9.30 oz/yd2 (+/- 5%) |
9.20 oz/yd2 (+/- 5%) |
ASTM D3776 |
| Width-Min. |
63.5” |
>63.0” cuttable |
|
Tear Strength (lbs W X F) |
11.4 x 10.1 |
>7.0 x >7.0 |
ASTM D1424 |
Tensile Strength (lbs W X F) |
200 x 95 |
>130 x >80 |
ASTM D5034 |
| Air Permeability (cfm) |
28 |
>20 |
ASTM 737 |
Laundry Shrinkage (W X F) |
2.4% x <0.4% |
<3.0% x <3.0% |
ASTM 1506 AATCC 135-3, IV, Aiii |
10 IL** Shrinkage (W X F) |
3.2% x <0.6% |
<5.0% x <5.0% |
** Wash Method as specified by NFPA 2112 |
| TPP (contact/spaced) |
10.9/12.0 |
>3/6 |
NFPA 2112-2007 |
| Vertical Flame |
3.04” |
<4.0” |
ASTM D6413 |
| Thermal Shrinkage |
2.8% |
<10% |
NFPA 2112-2007 |
| Arc Rating (ATPV) |
12.4 cal/cm2 |
>8.0 |
ASTM F1959 |
| Thermal Manikin |
9.6% avg. |
<50% |
ASTM F1930 |
Certified to ASTM F1506 (NFPA 70E HRC2),CGSB 155.20, NFPA 2112
*Note: "Process Averages" are historical estimates, actual results may vary.
| 11oz. Duck |
Process Averages* |
Specs* |
Test Method |
| Weight |
11.2 oz/yd2 (+/- 5%) |
11.5 oz/yd2 (+/- 5%) |
ASTM D3776 |
| Width-Min. |
67.3” |
>65.0” Cuttable |
|
Tear Strength (lbs W X F) |
>14.0 x >14.0 |
>10.0 x >10.0 |
ASTM D1424 |
Tensile Strength (lbs W X F) |
>250 x 124 |
>150 x >100 |
ASTM D5034 |
| Air Permeability (cfm) |
9.3 |
>5 |
ASTM 737 |
Laundry Shrinkage (W X F) |
2.2% x 1.6% |
<3.0% x <3.0% |
ASTM 1506 AATCC 135-3, IV, Aiii |
10 IL** Shrinkage (W X F) |
3.1% x 1.6% |
<5.0% x <5.0% |
** Wash Method as specified by NFPA 2112 |
| TPP (contact/spaced) |
TBD |
>3/6 |
NFPA 2112-2007 |
| Vertical Flame |
2.95” |
<4.0” |
ASTM D6413 |
| Thermal Shrinkage |
2.5% |
<10% |
NFPA 2112-2007 |
| Arc Rating (ATPV) |
13.9 cal/cm2 |
>12.0 |
ASTM F1959 |
| Thermal Manikin |
9.3% |
<50% |
ASTM F1930 |
Certified to ASTM F1506 (NFPA 70E HRC2),CGSB 155.20, NFPA 2112
*Note: "Process Averages" are historical estimates, actual results may vary.
Testing Videos |
| |
Amplitude 7oz. Fabric Kinectrics Arc Flash Test |
Amplitude 6oz. Fabric Air Permeability Test |
Amplitude 9oz. Fabric Pyroman 3 Sec. Burn Test |
|
 Flash Fire & Arc Flash Protection
 Higher Air Permeability More Comfort
 Excellent Durability Multiple Washes
 |
| |
Laundering Recommendations for Amplitude™ Flame Resistant 88/12 GarmentsYou may use standard home laundry detergents to wash Amplitude garments, but do not use chlorine
bleach, liquid peroxide bleaches or detergents containing hydrogen peroxide, fabric softeners or
starch. FR garments are performance based apparel. As such, the following laundering guidelines are
offered to ensure the garment performs in the manner it was designed on a consistent basis. Home Laundering When home washing garments made from Amplitude fabrics, you may use typical home laundry
detergents utilizing any wash temperature recommended by the detergent. Do not use other soaps (tallow
soaps contain animal fats which are flammable). Garment stains may be treated with a non-bleach type
commercial stain removal product. Repeated chlorine bleaching damages cotton and compromises fabric
strength. This may compromise the FR chemistry that is permanently chemically bound to the cotton in
the garment. Do not use home wash detergents containing hydrogen peroxide. Starch, fabric softener,
and other laundry additives can coat the fiber and mask flame resistant performance. They may also
serve as fuel in case of combustion. Flame resistant apparel should be washed using soft water (< 4
grains). Hard water can affect cleaning and may contain mineral salts that can cause insoluble deposits
on the fabric which may serve as fuel if garments are exposed to an ignition source. Commercial Laundering FR cotton and cotton blend fabrics have similar shrinkage expected in regular cotton garments.
Hotter water temperatures generally cause greater shrinkage, but may be required to remove certain
soils. It is important to remove flammable soils as they may compromise FR performance. Amplitude
fabrics maintain their FR performance for the useful life of the garment when washed according to care
instructions. During commercial laundering, Milliken recommends washing garments according to the
NFPA 2112 guidelines. For best colorfastness and garment appearance, use wash temperatures at or
below 150° F, however; garments may be washed at up to 165° F. Milliken recommends washing FR
garments separately from other garments. Use the correct water level for the load and do not overload
the machine. When drying, do not over dry the garment. If dried either too long or too hot you may get
excessive shrinkage (typical for cotton, in excess of 5%). If desired, iron with a synthetic/cotton iron
setting, with or without steam. Do not use starch. Dry Cleaning Amplitude cotton/nylon garments may be professionally dry cleaned. Either petroleum solvent or
perchloroethlyene can be used. When using petroleum solvent, it is necessary to ensure that all solvent
has been completely dried from the garment. With either solvent type, the garments must be free of
redeposition of any kind.
The information in this report is based on the results of testing in accordance with NFPA 2112-
2007, NFPA 70E-2004, ASTM 1506-02, and additional laboratory and commercial laundry testing. Guaranteed flame resistance for the life of the garment when washed according to care instructions.
Please Note: Amplitude fabrics are innovative, high-tech, flame resistant materials intended to be used in garments that
supplement personal protective equipment that reduce the flammability risks of momentary exposure to electric arc flash and
flash fire hazards. They may be used as a layer of, but are not intended for use as the primary protection in fire fighting garments
or other products subject to repeated or extended exposure to heat or flame except for Amplitude fabrics that are explicitly
certified in writing to meet NFPA 1977 for use in wildland fire fighting garments. Use caution near sources of flame or intense
heat and do not launder with bleach or fabric softeners. As each customer’s use of our product may be different, information we
provide, including without limitation, recommendations, test results, samples, care/labeling/processing instructions or marketing
advice, is provided in good faith but without warranty and without accepting any responsibility/liability. Each customer must test
and be responsible for its own specific use, further processing, labeling, marketing, etc. All sales are exclusively subject to our
standard terms of sale posted at www.milliken.com/terms (all additional/different terms are rejected) unless explicitly agreed
otherwise in a signed writing. |
 |
| |
Actionwear114 Melville St Saskatoon, Canada 866.933.3088 fax 306.934.2922 www.actiowearinc.com
|
|
Bulwark -VF Imagewear545 Marriott Drive Nashville, TN 37214 615.565.5000 www.bulwark.com |
|
Carhartt, Inc.5750 Mercury Drive Dearborn, MI 48126 800.833.3318 – toll free www.carhartt.com |
|
 |
| |
Codet/Big Bill FR294 Crawford Rd. Newport, VT USA 05855 800.992.6338 Fax 802.334.8268 www.bigbillfr.com
|
|
INTER Materials, LLC(Latin American Market) 13339 Olde Stonegate Road Midlothian, VA 23113 804.378.6034
|
|
Marv Holland Apparel Ltd.10939 - 120 Street Edmonton, AB T5H 3R3 Toll Free: 800.661.7269 Toll Free Fax: 800.361.0263 www.marvholland.com www.firewallfr.com |
|
| |
RPS Manufacturing Solutions726 Donald Preston Drive Wolfforth, TX 79382 800.288.8059 - toll free www.rps-solutions.com
|
|
UniFirst Corporation68 Jonspin Road Wilmington, MA 01887 800.455.7654 www.unifirst.com |
|
Western Shelter/Crew Boss815 Conger Street Eugene, OR 97402 541.743.4110 www.westernshelter.com
|
|
 |
| |
Winner Garments12003 Kingsway Avenue Edmonton, Alberta 866.956.8989 fax 877.455.7788 www.winnergarment.com |
|
Workrite® Uniforms500 East Third street Oxnard, CA 93032 800.521.1888 877.253.7040 - toll free fax www.workrite.com |
|
5.11 Tactical, Inc.4300 Spyres Way Modesto, CA 95356 866.451.1726 – toll free 209.527.1511 – fax www.511tactical.com |
|
 |
 |
| |
Amplitude® FR Fabric CertificationsPlease contact us for more information on Amplitude® FR fabrics.
Certified* - These fabrics receive a certificate of compliance as a UL recoginized component to the standard. |
| |
| FR Fabric Description |
70E Arc Flash ASTM 1506 |
Flash Fire NFPA 2112 |
Station Wear NFPA 1975 |
Wildland Fire NFPA 1977 |
Flash Fire CAN/CGSB 155.20 |
| Amplitude 11oz Twill |
meets HRC2 |
meets |
meets |
|
meets |
| Amplitude 5oz Poplin |
meets HRC1 |
|
Certified* |
|
|
| Amplitude 5.5oz Chambray |
meets HRC1 |
|
meets |
|
|
| Amplitude 6oz 4x1 Twill |
Certified* HRC2 |
Certified* |
meets |
|
Certified* |
| Amplitude 6oz Ripstop |
meets HRC1 |
|
meets |
Certified* |
|
| Amplitude 7oz Twill |
meets HRC2 |
Certified* |
Certified* |
Certified* |
Certified* |
| Amplitude 7oz Twill CS |
meets HRC2 |
meets |
meets |
meets |
meets |
| Amplitude 7oz Ripstop |
meets HRC2 |
|
meets |
Certified* |
|
| Amplitude 11oz Duck |
meets HRC2 |
meets |
meets |
|
meets |
| 12oz Denim (100% cotton) |
|
meets |
meets |
|
meets |
| 14oz Denim (100% cotton) |
|
|
meets |
|
|
| Amplitude 9oz Twill |
meets HRC2 |
Certified* |
meets |
meets |
Certified* |
|
|
|
|